Integrated Tube Type Ultrasonic Flow Meter (A+E 80FD)
    Publish time 2018-04-24 16:26    
Integrated Tube Type Ultrasonic Flow Meter (A+E 80FD)
Specifications:
Measurement Accuracy: Better than 1%,
Repeatability: Better than 0.2%
Measurement Period: 500ms (2 times per second, and 128 groups of data is collected during each period)
Working Power Supply: Isolated DC8~36V or AC85~264V is optional
Max Flow Velocity: 10m/s (flow resolution ratio 0.001m/s)
Display: 2*10 backlit display (Chinese and English are optional)
Operation: 4 magnetic keys window mode operation
Signal Input:
--3-way 4-29mA analog input, accuracy 0.1%, and pressure, liquid level, temperature signal can be inputted.
--2-way three-wire system PT100 platinum resistor
Signal Output:
--1-way isolated RS485 output
--1-way isolated OCT (The pulse width of 6~1000ms is programmable and the default value is 200ms)
--1-way relay output (The pulse width is 200ms)
--1-way 4-20mA output (active/passive output is optional)
--1-way Bi-directional Serial Universal Peripheral Interface that can be connected to multiple external devices throughcascade (such as mass data storage module)
Communication Protocol: MODBUS protocol
Other Functions:
--Automatically memorize the positive/negative/net accumulative flow of the past 512 days, 128 months, or past 10 years.
--Automatically memorize the past 30 times of power-on time, power-off time and flow, and realize the automatic or manual flow replenishment, which can be read via MODBUS Protocol.
--Software updating can be realized through code files sent through E-mail.
Power-off Protection: Datas can be stored without loss after 100, 000 hours' power off.
Protection Grade: IP68
Electrical Interface: M16*1.5


Letter Parameters Options
A Mainframe type: F1 Split wall-mounted type      
F2 Split anti-explosion type   
F3 Split panel-mounting type     
F4 Split transmitting type
Y Integrated type (local 4 magnetic keys cab be used to set parameters)
W water meter (battery powered, the users can browse the windows via magnetic keys)
M1 Module type (local 4 keys cab be used to set parameters)
M2 Module type (The users can browse the windows via local single key.)
S1 economical type ((local 4 magnetic keys cab be used to set parameters)
B Working power supply: A  AC (85-264VAC)         
B  Battery (3.6V lithium battery)         
D  DC (24V/8-36VDC)
C Thermal function  N (N/A)                                                             Y (Yes)
D Sensor type B1 Standard S1 type           
B2 Standard M1 type        
B3 Standard L1 type           
B4 High-temperature S1H type         
B5 High-temperature M1H type
C1 Standard Plug-in type     
C2 Cement Plug-in type    
C3 Water meter plug-in type
G1 Standard Sectional type (flange connection)                                                  
G2 Sanitary Sectional type (loose connection)
E Measurement tube diameter DN(mm)_____
F Pipeline material 0 Carbon steel 
1 Stainless steel 
2 Cast iron 
3 Fiberglass    
4 PVC           
5 Cement
G Nominal Pressure _____MPa
H Flow accumulative unit M stere                                                             L liter
Minimum reading (water meter) 1 (m 3 )      0.1 (0.1m 3 )   0.01 (0.01m 3 ) 0.001 (L)   0.0001 (0.1L)
I Thermal accumulative unit K Kc (Kilocalorie)                     
G Gj                            
B BTU (Applicable at abroad)
J Signal output: N No output      
A 4-20mA   
F Frequency output     
R Pulse output  
4 RS485 output
K Signal input: N No output              
1 1-way 4-20mA input             
2 2-way 4-20mA input       
3 3-way 4-20mA input
L Single cable length ____meters (split sectional sensor has single four-core cable, and the other sensors have two twin-core cables)