Unlike
older technologies, guided-wave radar (GWR) offers measurement readings
that are independent of the chemical or physical properties of the
process media with which it is in contact. Additionally, GWR performs
equally well in liquids and solids.
GWR is suitable for a variety of level measurement applications including those that involve:
--Unstable process conditions—Changes in viscosity, density, or acidity do not affect accuracy.
--Agitated
surfaces—Boiling surfaces, dust, foam, and vapor do not affect device
performance. GWR also works with recirculating fluids, propeller mixers,
and aeration tanks.
--High temperatures and pressures—GWR performs well in temperatures up to 220°C and can withstand pressures up to 60bar.
--Fine
powders and sticky fluids—GWR works with vacuum tanks filled with used
cooking oil as well as tanks holding paint, latex, animal fat, soybean
oil, sawdust, carbon black, titanium tetrachloride, salt, and grain.
With the advantage of easy installation and low power consumption, the
GWR level transmitter suits most liquid and solids level applications
and liquid interface applications.
Model Selection
Model | A+E 61L |
|
Sensor | A | ¢6mm 35000mm length cable |
B | ¢10mm 6000mm length probe | |
C | 6000mm length coaxial-dual probe | |
Explosion-proof | P | N/A, 4-20mA / HART |
I | Exd II CT6, 4-20mA / HART | |
Process connection | 1 | G1-1/2A , PN40 S.S. |
2 | DN50, PN40C, DIN2501 S.S. | |
3 | DN80, PN40C, DIN2501 S.S. | |
4 | DN100, PN16C, DIN2501 S.S. | |
5 | DN150, PN16C, DIN2501 S.S | |
Process temperature | 1 | Viton / -20 to 130 C (-4 to 266 F) |
2 | Kalrez / -40 to 150 C (-40 to 302 F) | |
3 | Viton with cooling fin / -40 to 200 C (-40 to 392 F) | |
4 | Kalrez with cooling fin / -40 to 220 C (-40 to 428 F) | |
Housing | A | Alumnium / IP68 |
Cable connection | M | M20*1.5 |
N | 1/2 NPT | |
Local display | Y | YES |
N | N/A | |
Programmer | Y | YES |
N | N/A | |
Special requirements | W | N/A |
Y | specialized | |
Length | L |
|
Website link