Support each other can overcome the challenge
Solidarity and Coordination can create the future together
                       
PRODUCT
About us
Flanged-Mounted Differential Pressure T
    Publish time 2018-04-24 17:10    
Flanged-Mounted Differential Pressure T
The seal diaphragm pressure transmitter is used for preventing media in the pipe from directly entering into the sensor module of the pressure transmitter, and it is connected to the pressure transmitter through capillary tubes filled with fluids.
This pressure transmitter is used to measure the liquid, gas and steam's pressure, then output the 4~20mA DC signal corresponding with the pressure.
As they can communicate with HART system, it can complete remote setting and surveillance.


Model Specification codes Descriptions
A+E-960CD                                                                    Diaphragm-sealed Differential Pressure Transmitter
MeasuringRange 4                                                             
5                                                             
0-10~40kPa
0-40~200kPa
Output Signal:
S                                                         4~20mA, HART protocol digital communication
Flange size D                                                     
E                                                       
F                                                    
2-inch(DN50)
3-inch(DN80)
4-inch(DN100)
Wetted material: S                                                  
H                                                    
T                                                  
SUS 316 (Note 1)
Hastelloy C-276
Tantalum
Protruded Length of Diaphragm 2                                                
4                                                
6                                                
50mm
100mm
150mm (Special tailored size)
Infusion A                                   
B                                     
C                                     
D                                     
E                                    
General type (silicone oil) -10~250 degree
General type (silicone oil) -30~180 degree
High-temperature type (silicone oil) 10~300 degree 
Low-temperature type (silicone oil) -50~100 degree
Oil-free type (fluorocarbon oil) -20~120 degree
Capillary tube length(m)                                  The stipulated capillary tubes length is 1~10m  (For example: 2m:02)
Display Header D                                         
E                                             
N                                         
Digital header
Digital header with setting button,
No header

Interfaces
1                                        
2                                        
3                                        
M20×1.5   internal thread
G1/2NPT    internal thread
1/2NPT      internal thread

Installation Bracket
B1                                
B2                                  
B3                                
Pipe bended mounting plate
Board bended mounting tubes;
Pipe flat mounting plate
Anti-explosion d                                 
i                                
Flame-proof type dIIBT4
Intrinsic safety type ia II CT 6